Harga Fire Alarm System Conventional

Harga Fire Alarm System Conventional

Kami merupakan distributor berbagai merk Fire Alarm System Equipment/Parts seperti ASENWAREDemcoContextPlus, HoosekiHong ChangHochiki, Multron, dll. Berikut dibawah ini merupakan daftar harga produk fire alarm system conventional / sistem alarm kebakaran konvensional, kami masih bisa memberikan harga yang lebih murah dari harga diskon dibawah untuk pembelian dalam kuantitas banyak.

Nama Produk Kode Produk Keterangan Harga Normal (Rp) Diskon (%) Harga Setelah Diskon (Rp)
Conventional fire alarm panel
1 zone
AW-CFP2166-1 1 fire alarm zone, 2 bell outputs,
1 fire relay,1 fault relay, metal shell
           4,123,800 20%                       3,299,040
Conventional fire alarm panel
2 zone
AW-CFP2166-2C 2 fire alarm zones, 2 bell outputs, 1 fire relay,
1 fault relay, plastic front cover ,metal back cover,embeded in wall type
           4,854,600 20%                       3,883,680
Conventional fire alarm panel
4 zone
AW-CFP2166-4C 4 fire alarm zones, 2 bell outputs, 1 fire relay,
1 fault relay, plastic front cover ,metal back cover,embeded in wall type
           5,637,600 20%                       4,510,080
Conventional fire alarm panel
6 zone
AW-CFP2166-6C 6 fire alarm zones, 2 bell outputs, 1 fire relay,
1 fault relay, plastic front cover ,metal back cover,embeded in wall type
           6,003,000 20%                       4,802,400
Conventional fire alarm panel
8 zone
AW-CFP2166-8C 8 fire alarm zones, 2 bell outputs, 1 fire relay,
1 fault relay, plastic front cover ,metal back cover,embeded in wall type
           6,368,400 20%                       5,094,720
Conventional fire alarm panel 12 zone AW-CFP2166-12 12 fire alarm zone, 2 bell outputs,
2 fire relay,1 fault relay, metal shell
         11,588,400 20%                       9,270,720
Conventional fire alarm panel 16 zone AW-CFP2166-16 16 fire alarm zone, 2 bell outputs,
2 fire relay,1 fault relay, metal shell
         13,833,000 20%                     11,066,400
Conventional fire alarm panel 20 zone AW-CFP2166-20 20 fire alarm zone, 2 bell outputs,
2 fire relay,1 fault relay, metal shell
         20,149,200 20%                     16,119,360
Conventional fire alarm panel 24 zone AW-CFP2166-24 24 fire alarm zone, 2 bell outputs,
2 fire relay,1 fault relay, metal shell
         22,393,800 20%                     17,915,040
Conventional fire alarm panel 28 zone AW-CFP2166-28 28 fire alarm zone, 2 bell outputs,
2 fire relay,1 fault relay, metal shell
         24,638,400 20%                     19,710,720
Conventional fire alarm panel 32 zone AW-CFP2166-32 32 fire alarm zone, 2 bell outputs,
2 fire relay,1 fault relay, metal shell
         26,883,000 20%                     21,506,400
Standby Battery B122AH 12V,2.3AH x 2pcs lead acid batteries            1,044,000 20%                           835,200
Conventional repeater AW-CRP2166 32 zone Led indicator, work with 2-32 zone panel via RS485            2,610,000 20%                       2,088,000
GSM module AW-GSM100 work with fire alarm panel for fire alarm notification by SMS            3,758,400 20%                       3,006,720
Conventional smoke detector AW-CSD381 Photo-electric
Work voltage: 9-28 VDC
Entrance LED output
Certificate: LPCB approved
              360,180 20%                           288,144
Conventional smoke detector AW-CSD311 Photo-electric
Work voltage: 9-28 VDC
Entrance LED output
              339,300 20%                           271,440
Conventional smoke detector with flash and buzzer AW-CSD812 Photo-electric
Alarm SPL.: ≥80dB Flash: Red 1Hz ,Work voltage: 9-28 VDC,Entrance LED output,Reset button
              485,460 20%                           388,368
Conventional heat detector AW-CTD382 Rate of rise 7.1℃/5S A2R
Work voltage: 9-28 VDC
Certificate: LPCB approved
              360,180 20%                           288,144
Conventional heat detector AW-CTD321 Rate of rise 7.1℃/5S A2R
Work voltage: 9-28 VDC
              339,300 20%                           271,440
Conventional heat detector AW-CTD322 Fix temperature: 60 ℃
Work voltage: 9-28 VDC
              187,920 20%                           150,336
Conventional smoke and heat detector AW-CSH831 Multi-detection
Work voltage: 9-28 VDC, Entrance LED output
              412,380 20%                           329,904
Conventional CO detector AW-CCO851 CO gas detector, Work voltage: 9-28 VDC, relay output               485,460 20%                           388,368
Conventional duct smoke detector AW-CSD313 Conventional smoke detector inside, sampling pipe and exhause pipe are not included.            3,393,000 20%                       2,714,400
Standalone gas detector AW-CGD2166 Operating Voltage: AC220V/50-60HZ.
Alarm Horn: >80dB
Value of Detection Threshold:
LPG Gas: 5000ppm (10%LEL)
Control valve is opptional
              652,500 20%                           522,000
Control valve               417,600 20%                           334,080
Conventional manual call point AW-CMC2166-5 Working voltage: 24VDC
With transparent protection cover, resetable with key
              198,360 20%                           158,688
Conventional manual push station AW-CMC2166-6 Working voltage: 9-28VDC
Dimensions: 140x105x45mm
Resetable with key
              563,760 20%                           451,008
Conventional fire bell AW-CBL2166 Working voltage: 24VDC
Alarm Current: ≤50mA
Diameter: 6 inch (150mm)
Sound level: ≥96dB
              360,180 20%                           288,144
Conventional strobe sounder AW-CSS2166-2 Working Voltage: 20-30VDC
Working Current (average): <50mA
Flash period: ≤90 times/min
Sound Pressure Level: ≥80dB
Type of Sound Alarm: 3
Size: 115x134x49mm
              412,380 20%                           329,904
Conventional sounder beacon AW-D316 Working Voltage: 20-30VDC
Working Current (average): <50mA
LPCB approved
           1,800,900 20%                       1,440,720
Conventional strobe sounder AW-CSS2166-3 Working Voltage: 15-30VDC
Working Current: ≤30mA
Flash period: ≤120 times/min
Sound Pressure Level: ≥80dB
Type of Sound Alarm: 1
Size: 84x81x56mm
              287,100 20%                           229,680
Conventional strobe sounder AW-CSS2166-4 Working Voltage: 12-30VDC
Working Current: ≤35mA
Flash period: ≤120 times/min
Sound Pressure Level: 95 ~ 115dB (Adjustable)
Type of Sound Alarm: 8
Size: 125x128x100mm
              934,380 20%                           747,504
Conventional strobe sounder AW-CSS2166-5 Working Voltage: 24VDC
Working Current: ≤350mA
Flash period: ≤120 times/min
Sound Pressure Level: 112dB
Type of Sound Alarm: 1 Types
Size: 180x140x73mm
              783,000 20%                           626,400
Conventional flash light AW-CFL2166 Working Voltage: 24VDC
Diameter: 72mm
Height: 45mm
              261,000 20%                           208,800
Entrance LED indicator AW-EL102 Working Voltage: 5VDC
Size: 70x30x50mm
              187,920 20%                           150,336
Infrared Linear Reflex Beam Smoke Detector with Reflector AW-BK901-25 Operating Voltage:20 V to 28 V DC,
Monitor range: 25m, 40m, 70m, 100m, LPCB approved
         10,701,000 20%                       8,560,800
AW-BK901-40
AW-BK901-70
AW-BK901-100
Beam smoke detector programmer AW-BK901CODER Ajust the beam distance from 20-100m            7,830,000 20%                       6,264,000
Explosion-proof ultraviolet flame detector AW-FD701E-UV Work voltage: 18V-30VDC
Working Current:
Monitoring state ≤15mA, Alarm status ≤35mA
Flame sensor: 1 UV
Explosion-proof: Exp II CT6
Protection: IP66
         14,877,000 20%                     11,901,600
Explosion-proof infrared flame detector AW-FD702E-IR2 Work voltage: 18V-30VDC
Working Current:
Monitoring state ≤15mA, Alarm status ≤35mA
Flame sensor: 2 IR
Explosion-proof: Exp II CT6
Protection: IP66
         16,443,000 20%                     13,154,400
Explosion-proof ultraviolet & infrared combined flame detector AW-FD703E-UVIR2 Work voltage: 18V-30VDC
Working Current:
Monitoring state ≤15mA, Alarm status ≤35mA
Flame sensor: 1 UV+ 2 IR
Explosion-proof: Exp II CT6
Protection: IP66
         46,458,000 20%                     37,166,400
Fire proof cable AW-FPC2X1.5 2 core x 1.5sqmm + 1 earth wire, 100meter/roll            3,445,200 20%                       2,756,160
AW-FPC2X2.5 2 core x 2.5sqmm +1 earth wire,100meter/roll            6,316,200 20%                       5,052,960